All trademarks are the property of their respective owners.
DescriptionThe ISO1050DUBR is a galvanically isolated CAN transceiver that meets the specifications ofthe ISO11898-2 standard. The device has the logic input and output buffers separated by a siliconoxide (SiO2) insulation barrier that provides galvanic isolation of up to5000 VRMS forISO1050DW and 2500 VRMS for ISO1050DUB. Used inconjunction with isolated power supplies, the device prevents noise currents on a data bus or othercircuits from entering the local ground and interfering with or damaging sensitive circuitry.
As a CAN transceiver, the device provides differential transmit capability to the bus anddifferential receive capability to a CAN controller at signaling rates up to 1 megabit per second(Mbps). The device is designed for operation in especially harsh environments, and it featurescross-wire, overvoltage and loss of ground protection from –27 V to 40 V and overtemperatureshutdown, as well as –12-V to 12-V common-mode range.
The ISO1050DUBR is characterized for operation over the ambient temperature range of –55°C to105°C.
Feature
- Meets the Requirements ofISO11898-2
 - 5000-VRMS Isolation (ISO1050DW)
 - 2500-VRMS Isolation(ISO1050DUB)
 - Fail-Safe Outputs
 - Low Loop Delay: 150 ns (Typical), 210 ns (Maximum)
 - 50-kV/μs Typical Transient Immunity
 - Bus-Fault Protection of –27 V to 40 V
 - Driver (TXD) Dominant Time-out Function
 - I/O Voltage RangeSupports 3.3-V and 5-V Microprocessors
 - VDE Approvalper DIN VDE V 0884-11:2017-01 and DIN EN 61010-1
 - UL 1577 Approved
 - CSA Approved for IEC 60950-1, IEC 61010-1, IEC 60601-1 3rd Ed (Medical)
 - TUV 5-KVRMS Reinforced Insulation Approval for EN/UL/CSA60950-1 (ISO1050DW-Only)
 - CQC Reinforced Insulation per GB4843.1-2011 (ISO1050DW-Only)
 - Typical 25-Year Life at Rated WorkingVoltage (see Application Report SLLA197 andLife Expectancy vs Working Voltage)
 
All trademarks are the property of their respective owners.
DescriptionThe ISO1050 is a galvanically isolated CAN transceiver that meets the specifications ofthe ISO11898-2 standard. The device has the logic input and output buffers separated by a siliconoxide (SiO2) insulation barrier that provides galvanic isolation of up to5000 VRMS forISO1050DW and 2500 VRMS for ISO1050DUB. Used inconjunction with isolated power supplies, the device prevents noise currents on a data bus or othercircuits from entering the local ground and interfering with or damaging sensitive circuitry.
As a CAN transceiver, the device provides differential transmit capability to the bus anddifferential receive capability to a CAN controller at signaling rates up to 1 megabit per second(Mbps). The device is designed for operation in especially harsh environments, and it featurescross-wire, overvoltage and loss of ground protection from –27 V to 40 V and overtemperatureshutdown, as well as –12-V to 12-V common-mode range.
The ISO1050 is characterized for operation over the ambient temperature range of –55°C to105°C.
 
  