久芯网

运放电源疑问?

avatar user1605125 提问时间: 2023-07-13 09:35:15 / 已解决
Other Parts Discussed in Thread: OPA277

为何有Specified Voltage Range和Operating Voltage Range两种定义?谢谢!

5个回答
  • avatar Vera Mao
    回答时间: 2023-07-13 10:07:29

    请问你指的是哪颗器件上有同时这两种定义?

    一般主要区分的是absolute rating和recommended operating voltage range 或specified operating voltage range, 后两个表达的是同一个意思.

  • avatar user1605125
    回答时间: 2023-07-13 10:39:10

    opa277的datasheet上如下:

    POWER SUPPLY

    Specified Voltage Range VS  ~   ±5     ±15   V

    Operating Voltage Range ±2 ~   ±18  V

  • avatar Vera Mao
    回答时间: 2023-07-13 11:07:22

    OPA277的指标书上看, Specified Voltage Range 指的是指标书上的大部分指标的测试条件. Operating Voltage Range 指的是该运放能工作的范围.

  • avatar Dale Li
    回答时间: 2023-07-13 11:31:21

    Specified Voltage Range: the specifications in data sheet will be met;

    Operating Voltage Range:the op amp will still function but all data sheet specifications may not be met,i.e. Output Swing to Rail, Aol, etc may be degraded.

  • avatar Jie Feng
    回答时间: 2023-07-13 11:50:34

    absolute rating一般是指在这个条件下,器件不会坏,超过就不保证了

    recommende operationg voltage range 和 specified operating voltage range 是一样的,也就是spec上面的参数范围在此电压下都能得到验证

    operating voltage 用的很少,一般应该很少出现在spec里面,更多是一种口头表达.它是指功能存在,但是性能不能保证